A 4-in-1 PCR test that delivers results with less than 1 minute of hands-on time.
We will be happy to give you a personal consultation and look forward to your request
Xpert Xpress CoV-2/Flu/RSV plus is a multiplexed real-time PCR test for the simultaneous qualitative detection and differentiation of SARS-CoV-2, influenza A, influenza B and/or RSV RNA in nasopharyngeal or anterior nasal swabs from people with signs and symptoms of respiratory viral infection.
A multi-gene target design gives target redundancy to reduce the impact of genetic drift and shift. Positive SARS-CoV-2-only or Flu-only results can be reported in as little as 25 minutes with early assay termination; the full run time is 36 minutes.
Multiplexing aims to give the right result first time and reduce reflex or confirmatory testing. The FDA-cleared version is for moderate-complexity settings and is CLIA-waived on GeneXpert Xpress systems.
| Catalog number | XPRS4PLEX-10 (10 tests) |
|---|---|
| Technology | Real-time RT-PCR |
| Targets | SARS-CoV-2 (RdRP, N2, E); Flu A (matrix, PB2, PA); Flu B (matrix, NS); RSV A/B |
| Sample type | Nasopharyngeal swab, anterior nasal swab |
| Transport medium | 3 mL UTM/VTM or 2 mL eNAT |
| Time to result | ≈36 min; 25 min with EAT (SARS-CoV-2 or Flu positive) |
| Hands-on time | < 1 min |
| Testing mode | On-demand, minimum batch of 1 |
| Sample extraction | Automatic/integrated |
| Precision pipetting | Not required |
| Controls | Sample Processing Control, Probe Check Control |
| System | GeneXpert Xpress (CLIA-waived), GeneXpert Dx/Infinity |

Key information for testing samples collected from individuals with signs of respiratory infection.
Nasopharyngeal and anterior nasal swabs from individuals with signs of respiratory infection.
The FDA-cleared product is intended for moderate-complexity settings and for CLIA-waived use on GeneXpert Xpress systems.
Zeptometrix NATtrol Flu/RSV/SARS-CoV-2 (positive) and Coxsackievirus A9 (negative).
A verification guide is available for preparing contrived positive samples.
The instructions and Assay Definition File are supplied electronically, and the ADF CD with the first order.
Both versions are technologically identical: no change in chemistry, sample processing, consumables or assay parameters.
The versions are not interchangeable; the ADFs can be installed on the same computer at the same time.
The FDA version no longer supports nasal aspirate/wash and saline; NPS and NS samples at -80ºC are acceptable.
The EUA version is not compatible with the GeneXpert System with Touchscreen.